Local Law 11Facade Inspection & Safety Program · Cycle 10

Every Local Law 11 filing in New York, discoverable.

Look up any building's Cycle 10 filing window for free, then put it on watch. BMMP tracks its FISP status, deadline and paper trail, and tells you when something changes.

[COVERS]Buildings over six stories
[CYCLE]Every five years · 10A, 10B, 10C
[FILED BY]A QEWI, through DOB NOW: Safety
[REPORT]TR6, within 60 days of inspection
↳ The city right nowCounts from the app · Nov 2026
17,000+Buildings coveredEvery building FISP applies to, in all five boroughs.
7,748Need repairsFiled with conditions that call for work.
2,305Late on inspectionPast their window with no report on file.
3,782In the current windowSub-cycle 10A buildings due to file now.
↳ Free property lookup

When is your building due?

Enter a tax block number or a ten-digit BBL. Your sub-cycle is set by the last digit of the block.

[CYCLE 10 DEADLINE CHECKER]
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
Or pick the last digit of your block
[RESULT]Sub-cycle and time remainingYour filing window appears here.
Sub-cycleBlock ends inFiling window
10A4, 5, 6, 9Feb 21, 2025 to Feb 21, 2027
10B0, 7, 8Feb 21, 2026 to Feb 21, 2028
10C1, 2, 3Feb 21, 2027 to Feb 21, 2029

A note on Local Law 49 of 2025: DOB has not yet published a replacement schedule, so the published Cycle 10 windows above still apply.

↳ The law, in short

What Local Law 11 asks of a building.

FISP exists so that nothing falls from a facade onto a New York sidewalk. Every covered building is examined, classified and filed, cycle after cycle.

[01 · WHO]Buildings over six stories

Every exterior wall and its appurtenances: balconies, railings, fire escapes, parapets and anything fixed to the facade.

[02 · WHEN]Once every five years

Filing is staggered into three two-year windows, A, B and C, set by the last digit of the tax block.

[03 · BY WHOM]A Qualified Exterior Wall Inspector

A New York licensed engineer or architect who meets DOB’s experience requirements, hired by the owner.

[04 · HOW]Hands-on, close-up exams

Physical examinations from scaffold or lift at intervals of no more than 60 feet along street-facing walls, with probes where cavity walls call for them.

[05 · WHAT IS FILED]A TR6 report

The QEWI classifies the building and files the report through DOB NOW: Safety within 60 days of the inspection.

[06 · EVERY YEAR]Parapet observations

Separate from the five-year cycle: an annual observation of every parapet facing a public right-of-way.

↳ Report classifications

Three classes, plus the buildings that never filed.

The same four states you see on the BMMP map.

[CLASS №1]Safe

No action needed until the next cycle.

[CLASS №2]SWARMP

Safe With a Repair and Maintenance Program. Repairs are due within up to five years, and the same condition cannot be SWARMP two cycles in a row.

[CLASS №3]Unsafe

Immediate public protection, usually a sidewalk shed, with repairs due within 90 days unless DOB grants an extension.

[CLASS №4]No report

A covered building with nothing on file for the cycle. Penalties accrue monthly.

↳ Penalties and fees

What missing the window costs.

[DOB CIVIL PENALTIES]
ViolationPenalty
Late filing$1,000 per month
Failure to file$5,000 per year, plus the monthly penalty
Uncorrected SWARMP conditions$2,000
Uncorrected Unsafe conditions$1,000 per month, plus sidewalk shed penalties
[DOB FILING FEES]
FilingFee
Initial report$425
Amended or subsequent report$425
Extension request$305 each
Penalty waiver request$140

Fees are paid through DOB NOW: Safety.

↳ Local Law 11 on BMMP

The whole program, on one map.

BMMP gathers every FISP filing in the five boroughs and makes it discoverable, from the city down to the contents of a single TR6.

[STATUS]Every lot, colored by class

Safe, SWARMP, Unsafe or No report, for the current cycle and every one before it.

[DEADLINES]Sub-cycle and time remaining

Each building carries its next filing window, so nothing arrives as a surprise.

[PEOPLE]Owner, manager, QEWI

The names on the filings, with portfolios and work histories behind them.

[PAPER TRAIL]TR6 contents, permits, sheds

Conditions and remedies as reported, the repair jobs that followed and the protection still standing.

↳ FISP Watch

Put a building on watch.

Alerts 12, 6 and 3 months before its filing window closes, and whenever its DOB status changes.

[WATCH MY BUILDING]
Send me
Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.
[12 · 6 · 3]Months before the window closes, you hear from us.
[STATUS]A new filing or a change of class reaches you the day it posts.
[FREE]Watching a building costs nothing. Portfolios and teams run on BMMP licenses.
↳ Questions

Local Law 11, answered.

Which buildings does Local Law 11 cover?

Buildings in New York City taller than six stories. The law covers every exterior wall and the things attached to it, including balconies, railings, fire escapes and parapets.

How do I know which sub-cycle my building is in?

It is set by the last digit of your tax block. Blocks ending in 4, 5, 6 or 9 file in 10A, blocks ending in 0, 7 or 8 file in 10B, and blocks ending in 1, 2 or 3 file in 10C. The lookup above does it for you.

Who can perform the inspection?

A Qualified Exterior Wall Inspector, or QEWI: a New York licensed professional engineer or registered architect who meets DOB’s experience requirements. The owner hires the QEWI, and the QEWI files the report.

What is a TR6?

The technical report a QEWI files with DOB at the end of a critical examination. It classifies the building as Safe, SWARMP or Unsafe and records the conditions found and the remedies recommended. It is filed through DOB NOW: Safety within 60 days of the inspection.

What happens after an Unsafe filing?

Public protection goes up immediately, usually a sidewalk shed. Repairs are due within 90 days unless DOB grants an extension, and an amended report is filed once the work is complete.

Can a building stay SWARMP?

Not for the same condition. A SWARMP item has to be repaired by the date the QEWI sets, and a condition reported as SWARMP in one cycle cannot be reported as SWARMP again in the next.

Are parapet observations part of FISP?

No. They are a separate annual requirement for parapets facing a public right-of-way, whatever the height of the building. FISP Watch can remind you of both.

Where does BMMP get its data?

From public records, gathered from the scattered places they live into one map, down to the contents of each building’s TR6 report.

Is the lookup free?

Yes. The deadline checker and FISP Watch are free for any building. BMMP licenses are for firms that work across portfolios, neighborhoods and the whole city.