Look up any building's Cycle 10 filing window for free, then put it on watch. BMMP tracks its FISP status, deadline and paper trail, and tells you when something changes.
Enter a tax block number or a ten-digit BBL. Your sub-cycle is set by the last digit of the block.
A note on Local Law 49 of 2025: DOB has not yet published a replacement schedule, so the published Cycle 10 windows above still apply.
FISP exists so that nothing falls from a facade onto a New York sidewalk. Every covered building is examined, classified and filed, cycle after cycle.
Every exterior wall and its appurtenances: balconies, railings, fire escapes, parapets and anything fixed to the facade.
Filing is staggered into three two-year windows, A, B and C, set by the last digit of the tax block.
A New York licensed engineer or architect who meets DOB’s experience requirements, hired by the owner.
Physical examinations from scaffold or lift at intervals of no more than 60 feet along street-facing walls, with probes where cavity walls call for them.
The QEWI classifies the building and files the report through DOB NOW: Safety within 60 days of the inspection.
Separate from the five-year cycle: an annual observation of every parapet facing a public right-of-way.
The same four states you see on the BMMP map.
No action needed until the next cycle.
Safe With a Repair and Maintenance Program. Repairs are due within up to five years, and the same condition cannot be SWARMP two cycles in a row.
Immediate public protection, usually a sidewalk shed, with repairs due within 90 days unless DOB grants an extension.
A covered building with nothing on file for the cycle. Penalties accrue monthly.
Fees are paid through DOB NOW: Safety.
BMMP gathers every FISP filing in the five boroughs and makes it discoverable, from the city down to the contents of a single TR6.
Safe, SWARMP, Unsafe or No report, for the current cycle and every one before it.
Each building carries its next filing window, so nothing arrives as a surprise.
The names on the filings, with portfolios and work histories behind them.
Conditions and remedies as reported, the repair jobs that followed and the protection still standing.
Alerts 12, 6 and 3 months before its filing window closes, and whenever its DOB status changes.
Buildings in New York City taller than six stories. The law covers every exterior wall and the things attached to it, including balconies, railings, fire escapes and parapets.
It is set by the last digit of your tax block. Blocks ending in 4, 5, 6 or 9 file in 10A, blocks ending in 0, 7 or 8 file in 10B, and blocks ending in 1, 2 or 3 file in 10C. The lookup above does it for you.
A Qualified Exterior Wall Inspector, or QEWI: a New York licensed professional engineer or registered architect who meets DOB’s experience requirements. The owner hires the QEWI, and the QEWI files the report.
The technical report a QEWI files with DOB at the end of a critical examination. It classifies the building as Safe, SWARMP or Unsafe and records the conditions found and the remedies recommended. It is filed through DOB NOW: Safety within 60 days of the inspection.
Public protection goes up immediately, usually a sidewalk shed. Repairs are due within 90 days unless DOB grants an extension, and an amended report is filed once the work is complete.
Not for the same condition. A SWARMP item has to be repaired by the date the QEWI sets, and a condition reported as SWARMP in one cycle cannot be reported as SWARMP again in the next.
No. They are a separate annual requirement for parapets facing a public right-of-way, whatever the height of the building. FISP Watch can remind you of both.
From public records, gathered from the scattered places they live into one map, down to the contents of each building’s TR6 report.
Yes. The deadline checker and FISP Watch are free for any building. BMMP licenses are for firms that work across portfolios, neighborhoods and the whole city.